City of Taylorville

Storm Water Separation

WARD I

1996                                              $388,000.00              $200,000.00 CDAP Grant

            1356 feet 30" Force Main                                    $188,000.00 City Portion

            979 feet 12" Storm Sewer

            15 feet 15"  Storm Sewer

            656 feet 24"  Storm Sewer

            540 feet 30"  Storm Sewer

            20 feet 36"  Storm Sewer

                       

1996   Cleveland to Long to Bidwell Street                         $50,846.75 Total City Funds

            902 feet 12"  Storm Sewer

            480 feet 15"  Storm Sewer

 

1998    Esther to Ash on Shawnee                                      $80,000.00 Total DCCA Grant

            116 feet 12"  Storm Sewer                      Total        $518,846.75

            1095 feet 24"  Storm Sewer             City Portion:    $238,846.75

 

    Lift Station with 6,000 gallon per minute pump put in at Cleveland/Long Streets

    Total Footage Ward I Storm Sewer: 6159 Feet

    Funding: 54% Grant Money  46% City Funds

 

    WARD III & IV

1996:    Phase I Spresser to Vandeveer  $522,000.00       $387,000.00 CDAP Grant

            3,641 feet 72"  Storm Sewer                                    $135,000.00 City Portion

 

1998:    Champley Ditch                                                      $126,000.00  100% DCCA Grant

             451 feet 84"    Storm Sewer

1999:   Phase II Vandeveer to East to Houston                   $245,000 100% DCCA Grant

            1,118 feet 72"  Storm Sewer

            604 feet 54"     Storm Sewer

2001:    Phase III From Vandeveer North on Houston to Adams then East on Adams to Simpson Street

            1,644 feet 54"  Storm Sewer         $686,000.00         $336,000.00 CDAP Grant

  1,522 feet 48"  Storm Sewer                                      $350,000.00 City Portion

            70 feet 36"       Storm Sewer

                                                                              Total:     $1,579,000.00

                                                       City Portion:     $485,000.00

  

Total Footage Ward III & IV Storm Sewer:              9,050 feet

   Funding: 70% Grant Money    30% City Funds

Ward I Storm Sewer Total Footage:                               6,159

Ward III & IV Storm Sewer Total Footage:                   9,050

Industrial Park Storm Sewer Total Footage:                  4,748

Total Storm Sewer Footage:                                            19,957 

 

INDUSTRIAL PARK STORM SEWER

                                                                                            $ 85,000.00 DCCA Grant

                                                                                            $136,748.00 Private Funds

                                                                        Total:          $221,748.00

2,683 feet 36"

2,065 feet 6 Force Main     

Total Footage Industrial Park Storm Sewer:                   4,748 feet:

Total Amount Spent for Storm Water Separation:   $2,319,594.75